40 code note(s) for Gweike · LF-3015CN. Add a code or symptom above to narrow further.
- Leveling failure, X, Z, B axis might reverse Gweike · Friendess TubePro Get a tech on it
- Setup error of travel range, edge seeking failure Gweike · Friendess TubePro Get a tech on it
- Incorrect height parameters Gweike · Friendess TubePro Get a tech on it
- Edge seeking failure Gweike · Friendess TubePro Get a tech on it
- Holder delay alarm Gweike · Friendess TubePro Get a tech on it
- Holder exceeds the position Gweike · Friendess TubePro Get a tech on it
- Holder alarm Gweike · Friendess TubePro Get a tech on it
- Chuck Gweike · Friendess TubePro Get a tech on it
- Excessive following error Gweike · Friendess TubePro Get a tech on it
- The follower is too close to the board Gweike · Friendess TubePro Get a tech on it
- Z axis -limit enabled Gweike · Friendess TubePro Get a tech on it
- Z axis +limit enable Gweike · Friendess TubePro Get a tech on it
- Z axis soft -limit enable Gweike · Friendess TubePro Get a tech on it
- Z axis soft +limit enable Gweike · Friendess TubePro Get a tech on it
- The capacitance is zero Gweike · Friendess TubePro Get a tech on it
- Abnormal increase of capacitance Gweike · Friendess TubePro Get a tech on it
- Capacitance decrease Gweike · Friendess TubePro Get a tech on it
- Capacitance increase Gweike · Friendess TubePro Get a tech on it
- Z axis servo alarm Gweike · Friendess TubePro Get a tech on it
- The control card is loose or pulled out Gweike · Friendess TubePro Get a tech on it
- Axis N positive / negative limit enable Gweike · Friendess TubePro Get a tech on it
- Axis N positive / negative soft limited position enable Gweike · Friendess TubePro Get a tech on it
- Axis N servo alarm Gweike · Friendess TubePro Get a tech on it
- Emergency stop Gweike · Friendess TubePro Get a tech on it
- Axis N returns ORG abnormally, motion axis remains working Gweike · Friendess TubePro Get a tech on it
- Failed to capture the switch signal when axis N returns ORG Gweike · Friendess TubePro Get a tech on it
- Switch signal keeps enable when axis returns ORG Gweike · Friendess TubePro Get a tech on it
- The position deviation of axis N double drive is too large Gweike · Friendess TubePro Get a tech on it
- User-defined alarm Gweike · Friendess TubePro Get a tech on it
- Illegal parameter configuration Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (please remove the alarm manually) Gweike · Friendess TubePro Get a tech on it
- Bus network alarm <network line XX is broken> Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (RTOS startup problem, system startup failed) Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (RTOS startup problem, not prepared) Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (RTOS startup problem, RTOS bin file version is incorrect) Gweike · Friendess TubePro Get a tech on it
- 0x9811000C — 0x9811000C — Bus network alarm (network card opening failed 0x9811000C) Gweike · Friendess TubePro Get a tech on it
- 0x9811001A — 0x9811001A — Bus network alarm (license error 0x9811001A) Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (network mismatch) Gweike · Friendess TubePro Get a tech on it
- Bus network alarm (configuration file read failure) Gweike · Friendess TubePro Get a tech on it
- 0x98110021 — 0x98110021 — Bus network alarm (cycle instruction loss 0x98110021) Gweike · Friendess TubePro Get a tech on it