Bottom cover glass temperature alarm
Raytools · Raytools Raytools BM06K 6 kW auto focus cutting head (3D and 90 degree variants)
What it means
Bottom protective glass is hotter than the set threshold (45 C example setting)
Can I keep running?
KB severity: Degraded
The knowledge base lists this as a degraded fault. You may finish the current job if it is safe to do so, but plan a technician visit before normal production.
The knowledge base records some owner-level checks for this fault. That is not a repair procedure from Kerfwise.
Where it points in the machine
thermal (bottom cover glass sensor)
Source: Raytools (empower.cn), 3.3 smart inspection
Source: Raytools (empower.cn), 3.3 smart inspection
Related symptoms in the knowledge base
Do not attempt DIY repair on high-voltage or Class 4 laser equipment. Get a technician. You can request one using the form on this page.
Get a tech on it